In the process of designing ventilation systemsIt is important that the fire protection of the air ducts be made correctly. The engineer must first of all take care of the safety of the people in the building. At the same time, properly performed protection of air ducts from high temperatures plays a significant role in this process.
To remove used air from a roomthe ventilation system of channels passing through all floors and crossing various fire compartments is applied. In the event that the fire protection of the air ducts has been ignored, in the event of a fire, smoke and a flame may spread in a matter of seconds from the place of ignition to the building as a whole.
In accordance with fire regulations andrules, each ventilation system must fully meet the requirements for fire protection of air ducts. It is possible to route air ducts through fire walls, partitions and ceilings only if all precautions are strictly observed. In addition, any possibility of transferring fire and smoke through floors and staircases should be excluded.
With the use of modern materials that provide protection of the duct system, you can simultaneously solve several problems:
The need for adequate fire protectionventilation systems forced to develop a wide range of methods and means that will reliably protect air ducts from exposure to high temperatures. To date, they have found their application in the arrangement of various types of channels, smoke removal and conditioning systems, as well as technological ventilation, gas systems and much more.
Depending on the characteristics of the action, chemical composition and application, the fire protection system of the air ducts can be represented in the following variations:
In our country the most popular meansfire protection of ventilation systems are finished materials. They are produced in the form of perlithophosphogel, asbestos-cement slabs and gypsum-fiber or gypsum boards. Their application allows to increase the overall fire protection index, and also creates an additional heat-absorbing and heat-shielding layer.
If the required fire safety indexis within 15-150 minutes, then when using flame retardants it can be up to 240 minutes. These materials do not pose a health hazard, although their price is quite comparable, and sometimes even lower than that of protective varnishes and paints.
In most cases, fire protection of air ducts is carried out mechanized, traditional and combined by means of special materials, compounds and coatings.
Combined treatment of air ducts combinesthe advantages of the two previous methods. It is made manually with the use of combined compositions that are applied to the metal surface, after which the composition falls on the foil basalt fabric. This method, due to its quality and economy, is very popular.